Nulka First Article Problem Log
Description of ProblemAdded byDateDrawingSheetGrid RefSuggested Solution - First ArticleSuggested Solution - Production ArticlesSolution BySolution DateSolved?
Item 3, confirmation of suitability to use.

Parts list:                       VG-95218-T60-B011

Picking list:                    VG-95218-T60-B011

Part mark on cable:     VG-95218-T60-B044



Advise internal sheath colours are, Grey, black, Brown. Await BAE instruction to proceed/New drawing
Ed Docherty06-Aug-19C51-A71-0491

RFI No.

NULKA 5B 2019-0002
Response: We accept the alternate. Engineering change will be raised to add the new cable to the parts list and amend the colour types listed on the wiring list with the only change being Blue to Grey.

Riccardo Viola12-08-19Yes
Confirmation of correct size and colour of markers

Item 8 is TMS-SCE-3/4-2.0-4, yellow maker sleeve
Item 4 is TMS-SCE-1/2-2.0-9, white marker sleeve.

Which is the correct colour and which is the correct size.
Ed Docherty06-Aug-19C51-A71-049-0011C3/B4 and C5/B5

RFI No.

NULKA 5B 2019-0003
Response: Engineering change will be raised to change item 4 from ½” White to ¾” white TMS marker sleeve as the cable diameter is greater than 15mm.

Alby Atkins12-08-19Yes
Confirmation of correct size and colour of markers

Item 10 is TMS-SCE-3/4-2.0-4, yellow maker sleeve
Item 6 is TMS-SCE-1/2-2.0-9, white marker sleeve.

Which is the correct colour and which is the correct size.
Vitor Santana15-Aug-19C51-A71-053-0011B3 and B5No
Confirmation of coding at RJ45 End

Drawing doesn't specify the coding of the X1 connector, which is the orientation of the RJ45 Plug
    Ed Docherty06-Aug-19C51-A71-075 Variant -002 and -0031B/C1

    RFI No.

    NULKA 5B 2019-0004
    Response: Engineering change will be raised to specify Code A fitment of the RJ45 plug into the connector for all configurations C51-A71-075-001/002/003.

    Riccardo Viola12-08-19Yes
    Part Number: C51-A71-095-002

    Item 6 is 100G0111-0.40-9 but we have received HP8-ZH-BFE-9 instead of 100G0111-0.40-9. Can you please confirm if we can use HP8 or we have to follow the bill of materials?
    Thanks in advance.
    Bruno Severo 07-Aug-19C51-A71-0951 OF 1C3No
    Note 5 on the drawing No C51-A93-145 says: Ring terminals to be labelled with service. There is nothing in the bill of material / drawing. Can you please tell us what type of material, position and description are for this labels? ThanksBruno Severo12-Aug-19C51-A93-1451 of 1C8No
    Part Number: C51-A73-013-001

    Note 3. RING TERMINALS TO BE LABELLED WITH SERVICE
    Material, text, and position are not specified.
    Vitor Santana12-Aug-19C51-A73-0131B8No
    When assembling connectors as 796859-3 (item 2), We use to fit the wires with ferrules and then tighten the screws down. Could you please tell us how to proceed in this kid of case from now on?
    Thanks in advance
    Bruno27-Aug-19C51-A71-0461 of 1C7No